COMPANY HEADER
Print Back

The OFS-2000F was designed specifically for Flares stack sand reports flow velocities from 0.03 - 170 m/sec with a ± 2% accuracy.

OSi's patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates an accurate average flow reading. It is the only flow sensor that gives a true non-contacting cross-stack flow measurement of the process. The OFS uses our EPA Method 14 approved optical scintillation technology. The optical scintillation technique relies on advanced Digital Signal Processing (DSP) electronics to "see" and measure the movement of turbulence found in a gaseous flow stream to provide highly accurate, path-averaged air velocity measurements. The accuracy of the OFS has been proven both in NIST's wind tunnel and in numerous real-world installations.

Unit of Measure

Advantages

Advantages

N/A
  • Cross stack/duct/pipe line measurement for more accurate flow readings.
  • Non-interfering; nothing in flow path.
  • Easy installation and optical alignment.
  • Great for J, Ja and Air-assist/Steam-assist.
  • Minimal upstream/downstream diameters; typically 2 & 1, not 20 & 10 like others.
  • Long-term reliability: no blowers or moving parts; operates unattended - 24/ 7/365.
  • Ultra-low maintenance design.
  • Rugged; designed for harsh environments.
  • Built in continuous self-test diagnostics.
  • Measurement unaffected by path length & media pressure, moisture & opacity.
  • No flow media high temp limits; sight glass windows provided for isolation from media.
  • Compliant with EPA 40CFR Parts 60 & 75.
  • CE, CSA & UL certified. OSi is ISO-9001.
  • Wide versatility, NIST tested and unbeatable combination of advanced technology, high performance and proven reliability!

OSF-2000F Options

OSF-2000F Options

N/A
  • Order Z-Purge Option for Class I Div I/II applications.
  • Standard Control Unit is rack mount; for wall mount, order 1910-301, NEMA4 Option.
  • For custom receiver cable length, order 1910-216-nnn where "nnn" is cable length in feet (max 300).

OSF-2000F Accessories

OSF-2000F Accessories

N/A
  • MZ-1179-00 Fiber Optic Modems (FOM) for distances to 1 mile (2 required)
  • MZ-0649-00 Limited Distance Modems (LDM) for distances > 100 feet to 3 miles. (2 required)
  • 1910-804 Laptop DB9 serial communications cable

Flow Performance

Measurement Technique

N/A Optical Scintillation (OSi Patented)

Dynamic Range

N/A 0.03 to 100 m/sec, bidirectional (higher rates possible on RS-232 port)

Accuracy (Absolute)

N/A ±0.01 m/sec basic -or- ±2% of reading, whichever is greater

Repeatability (Relative)

N/A ± 1% of reading

Long Term Drift

N/A Less than 1% per decade

Response Time

N/A Response 0.3 sec., Update: 3 sec., Averaging (selectable): 3-600 sec.

Automatic Calibration

N/A 2 or 3 point; user selectable interval -or- on external command

Sensor Health Monitoring

N/A Continuous self-test of voltages, performance, optics, etc.

Media/Environmental

Stack/Duct/Pipe Diameter (Standard)1 N/A 0.2 to 10 m

Media Temperature/Pressure/Humidity

N/A No effect on measurement

Media Transparency

N/A Up to 95% opacity (OFS-2000-FW recommended for high opacity)

Ambient Temperature

N/A -50 to 60 ºC-58 to 140 ºF

Condensing Humidity

N/A 0 to 100 %

Physical Specifications

Light Source

N/A Eye-safe 670 nm visible red LED, 5 deg. divergence angle

Sensor Head

N/A 9 x 9 x 13 in

Sensor Head Weight

N/A 13 lb

Note for Sensor Head

N/A With 4 in. scheduled 40 flange extender.
NEMA4 weather resistant.

Control Unit Dimensions: Rack Mount Version (Standard)

N/A 5 x 17 x 20 in

Control Unit Weight: Rack Mount Version (Standard)

N/A 13 lb

Note for Control Unit: Rack Mount Version (Standard)

N/A For indoor use.

Control Unit Dimensions: NEMA4 Wall Mount (Optional)

N/A 12 x 16 x 10 in

Control Unit Weight: NEMA4 Wall Mount (Optional)

N/A 15 lb

Note for Control Unit: NEMA4 Wall Mount (Optional)

N/A For outdoor/factory floor use.

Electrical Specifications

User Interface

N/A RS-232 serial I/O and / or 4-20 mA optically isolated current loop; Also two sets of relay contacts for fault and calibration indication.

Power for Transmit Head

N/A Universal 100-240 VAC, 50/60 Hz, 12 VA (fused & surge protection)

Power for Control Unit

N/A Universal 100-240 VAC, 50/60 Hz, 40 VA (fused & surge protection)

Cable between Control Unit and Receive Head

N/A 15 foot standard; to 300 foot optional (shielded, 10 cond., 22 AWG)
  • 1 Consult factory for other ranges.